型号 Model | ZHS-50-3P-A ZHS-50-3P-B ZHS-50-3P-C | ZHS-80-3P-A ZHS-80-3P-B ZHS-80-3P-C | ZHS-100-3P-A ZHS-100-3P-B ZHS-100-3P-C | ZHS-150-3P-A ZHS-150-3P-B ZHS-150-3P-C | ZHS-225-3P-A ZHS-225-3P-B ZHS-225-3P-C | ZHS-300-3P-A ZHS-300-3P-B ZHS-300-3P-C | |
内箱容积 Inner Volume | 50L | 80L | 100L | 150L | 225L | 300 | |
内箱尺寸(W*D*H mm) Inner Size | 400*350*350 | 400*400*500 | 500*500*400 | 500*500*600 | 750*500*600 | 750*500*600 | |
外箱尺寸(W*D*H mm) Overall Size | 以实际尺寸为主(两箱/三箱) Mainly in actual size (two boxes/three boxes) | ||||||
| 冲击温度Impact temperature | 低温冲击范围 Low temperature impact range | -10℃~-65℃(A系列: -40℃;B系列:-55℃;C系列:-65℃) | |||||
高温冲击范围 High temperature impact range | 60℃~+180℃ | ||||||
预热区升温时间 Preheating zone heating time | RT~+200℃≤50min,全程平均非线性,空载 Average nonlinearity throughout; unloaded | ||||||
| 预冷区降温时间 Cooling time in the precooling area | RT~-75℃≤100min,全程平均非线性,空载 Average nonlinearity throughout; unloaded | ||||||
预冷区温度范围 Temperature range of pre-cooling area | RT~-55℃ | ||||||
预热温度范围 Preheat zone temperature range | 60℃~+180℃ | ||||||
驻留时间 Sojourn Time | 30min | ||||||
恢复时间 Recovery Time | ≤5min | ||||||
| 温度波动度 Temperature Fluctuation | ±1℃ | ||||||
| 温度均匀度 Temperature Uniformity | ±2℃ | ||||||
转换时间 Conversion Time | ≤10s | ||||||
冷却方式 Cooling Method | 水冷/风冷 Water-cooled/Air-cooled | ||||||
| 参考标准 Standard Reference | GB/T 2423.1;GB/T 2423.2;GB/T2423.22; GJB/150.3; GJB/150.4;GJB/150.5 | ||||||